ORP Meter Water Quality Sensor Digital Electrode Probe

The LMS-ORP100 ORP Sensor is a high-precision digital electrode probe designed for accurate oxidation-reduction potential (ORP) measurement in various water quality applications. Utilizing an ionic electrode method, it offers a broad measurement range of ±1000.0 mV with exceptional accuracy of 0.1 mV. Encased in durable polymer plastic and featuring a compact, flat-structure design, the sensor is resistant to breakage and easy to clean. It supports automatic and manual temperature compensation, RS485 communication with Modbus RTU protocol, and is ideal for use in environmental monitoring, industrial processes, aquaculture, and laboratory research.

    Product Paramenters

    Product Name

    ORP sensor

    Model

    LMS-ORP100

    Measurement method

    Lonic electrode

    Range

    ±1000.0mV

    Accuracy

    0.1mV

    Power

    9-24VDC(Recommend12 VDC)

    Voltage

    8~24 VDC(55mA/ 12V)

    Material

    Polymer Plastic

    Size

    31mm*140mm

    Output

    RS-485, MODBUS protocol

    Product Features

    ① High-Accuracy ORP Measurement
    Employs an advanced ionic electrode method to deliver precise and stable ORP readings up to ±1000.0 mV with a resolution of 0.1 mV.
    ② Robust and Compact Design
    Constructed with polymer plastic and a flat bubble structure, the sensor is durable, easy to clean, and resistant to damage.
    ③  Temperature Compensation Support
    Allows both automatic and manual temperature compensation for improved accuracy under varying environmental conditions.
    ④ Modbus RTU Communication
    Integrated RS485 interface supports the Modbus RTU protocol, enabling seamless integration with data loggers and control systems.
    ⑤ Anti-Interference and Stable Performance
    Features an isolated power supply design that ensures data stability and strong anti-interference capability in noisy electrical environments.
    X2X6

    Applications

    application
    Industrial Wastewater Treatment
    In chemical, electroplating, or printing and dyeing industries, the sensor monitors ORP during wastewater oxidation/reduction processes (e.g., removing heavy metals or organic pollutants). It helps operators confirm whether the reaction is complete (e.g., sufficient oxidant dosage) and ensures treated wastewater meets discharge standards, reducing environmental pollution.
    Aquaculture Water Quality Management
    In fish, shrimp, or shellfish farms (especially recirculating aquaculture systems), ORP reflects the level of organic matter and dissolved oxygen in water. Low ORP often indicates poor water quality and high disease risk. The sensor provides real-time data, allowing farmers to adjust aeration or add microbial agents timely, maintaining a healthy aquatic environment and improving breeding survival rates.
    Environmental Water Quality Monitoring
    For surface water (rivers, lakes, reservoirs) and groundwater, the sensor measures ORP to assess ecological health and pollution status. For example, abnormal ORP fluctuations may indicate sewage inflow; long-term data tracking can also evaluate the effectiveness of ecological restoration projects (e.g., lake eutrophication control), providing support for environmental protection departments.
    Drinking Water Safety Supervision
    In water treatment plants, the sensor is used in raw water pretreatment, disinfection (chlorine or ozone disinfection), and finished water storage. It ensures disinfection is thorough (sufficient oxidation to inactivate pathogens) while avoiding excessive disinfectant residues (which affect taste or produce harmful by-products). It also supports real-time monitoring of tap water pipelines, safeguarding end-user drinking water safety.
    Laboratory Scientific Research
    In environmental science, aquatic ecology, or water chemistry laboratories, the sensor provides high-precision ORP data for experiments. For example, it can analyze the oxidation behavior of pollutants, study the relationship between temperature/pH and ORP, or verify new water treatment technologies—supporting the development of scientific theories and practical applications.
    Swimming Pool & Recreational Water Maintenance
    In public swimming pools, water parks, or spas, ORP (typically 650-750mV) is a key indicator of disinfection effectiveness. The sensor monitors ORP continuously, enabling automatic adjustment of chlorine dosage. This reduces manual monitoring efforts and prevents bacterial growth (e.g., Legionella), ensuring a safe and hygienic water environment for users.
    X9X8

    Digital RS485 water quality sensors technical data

    Digital RS485 Water Quality Sensors Technical Data
    No. Picture Product Name Model Range Accuracy Resolution
    1 Digital RS4851 DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L 0.01mg/L
    2 Digital RS4852 DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L 0.01mg/l
    3 Digital RS4853 Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb 1ppb
    4 Digital RS4854 PH sensor LMS-PH100 0-14pH ±0.02pH 0.01pH
    5 Digital RS4854 ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV 0.1mV
    6 Digital RS4856 EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm ±2.5%FS 1uS/cm,0.01mS/cm 1ppm
    7 Digital RS4857 Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm TDS:0-60000ppm Salinity: 0-500.00ppt ±1.5%FS 1uS/cm,0.01mS/cm 1ppm 0.01ppt
    8 Digital RS4858 COD sensor LMS-COD100 COD:0.1-1500mg/L TOC:0.1-750mg/L BOD:0.1-900mg/L Turbidity: 0.1-4000NTU Temperature range: 0-50 ℃ ±5% equiv.KHP Temperature: ± 0.5 ℃ 0.01mg/L equiv.KHP
    9 Digital RS4859 TSS sensor LMS-TSS100 0-50000mg/L/ 0-120000mg/L ±10%FS or 10 mg/L 0.1mg/L or 1mg/L
    10 Digital RS48510 Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU 0.01NTU
    11 Digital RS48510 Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU 0.01NTU
    12 Digital RS48512 CO2 sensor LMS-CO2100 2000PPM/10000PPM/50000PPM ±5%FS 1ppm
    13 Digital RS48513 Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    14 Digital RS48513 Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    15 Digital RS48510 Oil in Water sensor LMS-OIL100 0-50 mg/L ; 0-5 mg/L ±3%FS 0.01ppm
    16 Digital RS48510 Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS 0.1ug/L
    17 Digital RS48510 Blue-Green Algae sensor LMS-BGA100 0-2000,000 cells/ml ±3%FS
    18 Digital RS48518 Residual Chlorine sensor LMS-HCLO100 0 - 20.00 ppm ±5%FS 0.001 / 0.01ppm
    19 Digital RS48519 Marine Current sensor LMS-Current100 Temperature:-3℃ - 45℃ Velocity of flow:0-500 cm/s Flow direction:0-359.9° ±0.05℃ ±1 cm/s or ±2% ±2° Temperature: 0.001℃ Velocity of flow:0.1 cm/s Flow direction:0.1°
    Water Quality Analyzer Equipment
    No. Picture Product Name Model Size Power Display Output
    20 Digital RS48520 Protable DO Analyzer LMS-PA100 100mm*204mm < 0.5 W Power supply 7.5V, 5 batteries LCD display screen
    21 Digital RS48521 Multi-parameter Protable Water Analyzer LMS-PA100P 220mm*120mm*100mm Rechargeable lithium battery with 220v to dc charging adapter LCD display screen
    22 Digital RS48522 Multi-parameter Touch-screen Online Analyzer LMS-OA200T 180mmx230mmx100mm AC power supply: 220 VAC 7-inch touch screen